Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201054335 - Employee injured when fingertip amputated by falling metal

Accident Summary Nr: 201054335 -- Report ID: 0950642 -- Event Date: 08/21/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12607848409/13/200050930Sun Lite Metals

Abstract: At 1:30 p.m. on August 21, 2000, an accident occurred at the scrap metal reclamation yard of Sun-Lite Metal. Sun-Lite Metal sorts out scrap metal, cuts it into various sizes, and sells it to foundries. Employee #1 was a truck driver and at times also a metal sorter. At the time of the accident, Employee #1 was helping to lift up a piece of metal about 3-foot by 4-foot, weighing about 3000 pounds, to be loaded onto a truck for delivery to a customer. The metal was lying flat on the ground in the south end of the yard. In order for the metal to be lifted up fully, one side of the piece had to be raised up first to about 6-inches from the ground with one prong of the fork lift. At this point a small piece of metal, to serve as a wedge, had to be inserted between the metal and the ground so the forks could slide between the ground and the metal. As the metal was being lifted up to about 6-inches from the ground with a fork lift, Employee #1 inserted the small wedge piece of metal in between the ground and the metal to be loaded onto the truck. During the process of inserting the small wedge piece of metal, the load slipped off the fork and fell, smashing the top right middle finger of Employee #1. After investigation, it was found that the heavy piece of metal being lifted had not been secured against dangerous displacement. Employee #1 was taken to St Francis Medical Center where he was released the same day. On the following day, August 22, 2000, surgery was performed to amputate Employee #1's right middle fingertip at the clinic of Dr. Dwight Roberson.

Keywords: AMPUTATED, FINGER, CAUGHT BETWEEN, INDUSTRIAL TRUCK, SCRAP METAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126078484 Non Hospitalized injury Amputation Truck drivers, light

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close