Accident Summary Nr: 201050523 - Employee burned by refrigerant, later dies of complications

Accident Summary Nr: 201050523 -- Report ID: 0950642 -- Event Date: 05/19/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11979001207/29/199735810Mc Cann Engineering Mfg.

Abstract: Employee #1, a maintenance electrician for a company that manufactures beverage- dispensing equipment, was on the roof of a building, checking a compressor that was installed a few days previously, but was not functioning properly. He was visually examining the compressor when its line burst and R-22 refrigerant sprayed out onto his face, neck, and left hand. Employee #1 sustained first- and second-degree burns, for which he was treated and released from Glendale Memorial Hospital. He was subsequently admitted to Torrance Memorial Hospital when the burns became infected. While he was being treated for the infection, Employee #1 died from a pre-existing heart and respiratory condition.

Keywords: HEART, RESPIRATORY, COMPRESSOR, MAINTENANCE, RUPTURE, CHEMICAL BURN, NECK, FACE, HAND, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119790012 Fatality Burn(Chemical) Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close