Accident Report Detail

Accident Summary Nr: 201044898 - Excavator Is Killed in Pressurized Release of Grout and Rock

Accident Summary Nr: 201044898 -- Report ID: 0953220 -- Event Date: 06/11/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31600307806/11/20121622237990Vegas Tunnel Constructors

Abstract: On June 11, 2012, Employee #1, of Vegas Tunnel Constructors, Las Vegas, NV, was part of a swing shift crew excavating a tunnel. They were using a tunnel boring machine (TBM). The TBM had been excavating in closed mode for approximately 17 days. Closed mode is a term used to describe one of two modes of operation this TBM was capable of performing, the other being open mode. Closed mode excavation involves the pressurization of the cutterhead and face of the TBM to support the ground and/or control excessive groundwater inflows. The position of the TBM found it excavating through a large vertical fault zone that later became the Detachment Fault. The ground conditions required the TBM face to be pressurized to approximately 13 bars of pressure. The grout being injected in the annular space was being pumped in at approximately 14 bars. The swing shift had begun work and was preparing to erect a ring segment set; Ring #135. The swing shift began to build Ring #135 at about 4:00 p.m. The first segment was successfully installed in the tunnel crown (top of the tunnel). The crew then began to install the second segment, which was to be placed in front of the keystone of Ring #134. Three hydraulic rams, including one abutting the keystone of Ring #134, were slowly retracted. Almost as soon as the retraction began, a loud pop was heard. Some members of the crew reported hearing a second pop. The keystone for Ring #134 had shifted forward approximately 4 inches. The come-a-long did not hold the forces exerted, and the gears were stripped out. This shift permitted grout and other materials such as rocks to escape the annulus at a pressure of approximately 14 bars (200 psi). Employee #1 was standing in front of the area where the gap developed. He was struck and killed by the moving grout and rocks. Coworkers found Employee #1 and removed him from the tunnel.

Keywords: EXCAVATION, TUNNEL, ROCK, CONSTRUCTION, EQUIPMENT FAILURE, CRUSHED, HIGH PRESSURE, STRUCK BY, BORING MACHINE, PRESSURE RELEASE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition $20,000,000 and over X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 316003078 Fatality Bruise/Contus/Abras Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Backfilling and compacting
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.