Accident Summary Nr: 201044039 - Employees Are Overcome by Carbon Monoxide in Tunnel

Accident Summary Nr: 201044039 -- Report ID: 0953220 -- Event Date: 12/10/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31289611112/10/20081771238990Hydro Arch

Abstract: On December 10, 2008, Employees #1 though #5, with Hydro-Arch, were repairing the floor of the south bypass conduit water tunnel located under Lake Las Vegas in Henderson, Nevada. The tunnel was two miles long and seven feet in diameter. They had cleaned the floor of the tunnel and were preparing to pour concrete on the tunnel floor. Two coworkers initially entered the tunnel with a golf cart at approximately 7:45 a.m. to drop off equipment after activating the ventilation fan from outside. Approximately 8:00 a.m., they exited the tunnel to wait for the concrete truck to arrive at the site. Approximately 9:30 a.m., Employees #1 through #5 entered the tunnel with the concrete load. Concrete was carried in eight buggy carts pulled by bobcat. Behind them, the mechanic and Project Superintendent followed on a propane-operated golf cart. Around 10:00 a.m., these employees arrived at the work location and found that the mechanical ventilation fan had been shut down. Several unsuccessful attempts were made to start the fan. The Project Superintendent and foreman decided that work would continue, after measuring the natural air flow using a handheld Mini Thermo-Anemometer by Extech Instrument. At 11:15 a.m., the foreman radioed from inside tunnel that employees were experiencing difficulty breathing, chest pains, and fatigue. The project superintendent sent golf carts and removed all employees from the tunnel about 12:16 p.m. Employees #1 through #5 were treated for asphyxia and carbon monoxide poisoning at University Medical Center (UMC) in Las Vegas and St. Rose De Lima in Henderson. All five employees were treated at UMC with hyper-oxygen therapy. Reports from the employer confirmed that employees' carboxy-hemoglobin concentrations ranged between 12 and 32.

Keywords: CHEST, TUNNEL, ASPHYXIATED, REPAIR, VENTILATION, INHALATION, RESPIRATORY TRACT, CARBOXYHEMOGLOBIN, CARBON MONOXIDE, CONCRETE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Maintenance or repair $1,000,000 to $5,000,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312896111 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Asphyxiation/inhalation of toxic vapor
2 312896111 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Asphyxiation/inhalation of toxic vapor
3 312896111 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Asphyxiation/inhalation of toxic vapor
4 312896111 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Asphyxiation/inhalation of toxic vapor
5 312896111 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.