Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201043437 - Employee killed when pinned by backhoe bucket

Accident Summary Nr: 201043437 -- Report ID: 0953220 -- Event Date: 10/31/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31163434910/31/20071521236115Pulte Homes Of Nevada
Inspection NrDate OpenedSICNAICSEstablishment Name
31163432310/31/20071794238910Town & Country Construction, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31163423210/31/20071741238140Cedco, Inc.

Abstract: On October 31, 1007, Employee #1 was scoping the grade while acoworker from another company was using a backhoe to dig footings along a bank. The backhoe had been turned off while Employee #1 was scoping the grade; when he finished, the backhoe operator restarted his vehicle to move it farther along the site to continue with the digging. The backhoe operator turned the seat to the loader position and began to lift the loader bucket when he heard a cry. The backhoe boom had moved and the bucket had pinned Employee #1 against the footing wall. The backhoe operator immediately swung back around, releasing him. Emergency Services was called and began CPR upon arrival. Employee #1 was transported to a nearby hosptal, where he was pronounced dead.

Keywords: CPR, EQUIPMENT OPERATOR, EARTHMOVING EQUIP, BACKHOE BUCKET, LOADER/BACKHOE, STRUCK BY, INATTENTION, BACKHOE BOOM, PINNED, CONSTRUCTION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $20,000,000 and over X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311634349 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
2 311634323 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
3 311634232 Fatality Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.