Accident Summary Nr: 201041514 - Employee Receives Electric Shock While Using Band Saw

Accident Summary Nr: 201041514 -- Report ID: 0953220 -- Event Date: 08/14/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30678922308/19/20035411445110Albertson'S Food And Drug Store

Abstract: On August 14, 2003, an employee, a butcher, moved 250v electrical cord for band saw out of the way after setup getting ready to cut meat. The employee moved the cord with his left hand and received an electrical shock. The equipment was cleaned with high pressure water. The receptacle had a crack in the seal causing water to get in the plug, causing it to short when the cord was moved. The equipment had been washed down at the end of the shift the day before. The employee received electric shock but was not hospitalized.

Keywords: BANDSAW, ELECTRIC SHOCK, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306789223 Non Hospitalized injury Electric Shock Butchers and meat cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.