Accident Summary Nr: 201041324 - Employee's struck by flying object while pipe cleaning

Accident Summary Nr: 201041324 -- Report ID: 0953220 -- Event Date: 02/20/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30612086603/17/20031542236220Northern Pipeline Construction Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
30612140103/25/20031794238910Southwest Gas Corporation

Abstract: On February 20, 2003, a crew was cleaning out a 650-ft pipeline using a pig. The first set of pigs were put into the launcher and sent through the pipeline with no problems. A second set of three, 6-in. pigs, were placed in the launcher. The flange was secured by tightening six metal nuts to the bolts of the cover and then compressed air applied. Pig Number 1 moved to the end of the launcher and into the pipeline. Employee #1 walked over to the launcher to assist the foreman. After several minutes the compressed air was bled off and the cover opened. The foreman pushed Pig Number 2 and Number 3 into the end of the launcher using a rod, again secured the cover and applied compressed air. Pig Number 2 moved to the end of the launcher and into the pipeline. Again, several minutes passed, the compressed air was bled off and the Foreman and Employee #1 removed the nuts from the cover. The foreman opened and moved the cover over to the left side of the launcher but before the foreman could use the rod to push Pig Number 3 to the end of the launcher, Employee #1 looked into the launcher to see where Pig Number 3 was. Employee #1 backed away from the opening an estimated 4 to 6 ft, bent down, put his left hand up to shield his eyes from the sun and looked into the launcher opening. Employee #2, standing 3 to 4 ft behind Employee #1, also looked into the launcher. Pig Number 3 shot backwards out of the launcher striking Employee #1 in the face and left forearm and then struck Employee #2 in the right arm. Employee #1 was hospitalized with fractures to his face and left wrist. Employee #2 did not require any medical treatment.

Keywords: CLEANING, PIPE, FRACTURE, PIPELINE, STRUCK BY, ARM, FLYING OBJECT, FACE, WRIST
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $250,000 to $500,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 306120866 Fatality Fracture Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile
2 306120866 Non Hospitalized injury Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile
3 306121401 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.