Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201040425 - Employee killed in fall down stage lift shaft

Accident Summary Nr: 201040425 -- Report ID: 0953220 -- Event Date: 12/29/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30077303312/29/199770110Rio All-Suite Hotel & Casino
Inspection NrDate OpenedSICNAICSEstablishment Name
30150440312/29/199779220Cinema Services

Abstract: Employee #1 was killed when he fell into a stage lift shaft.

Keywords: WORK RULES, SHAFT, LIGHTING, ELEVATOR SHAFT, FALL, FALL PROTECTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300773033 Occupation Not Listed
2 301504403 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close