Accident Summary Nr: 201037561 - Employee Dies in Fall Into 15 Ft Pit

Accident Summary Nr: 201037561 -- Report ID: 0950635 -- Event Date: 09/14/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30547961009/14/20051799238990Ancon Marine

Abstract: At approximately 8:47 p.m., on September 14, 2005, Employee #1 of an industrial cleaning company and often does contract work in refineries. In this particular contract, employer was given the task of cleaning waste tanks. Employees #1 through #3 were on the night shift on the night of the accident. After the tanks had been emptied of water, the employees descended into the tanks one by one to manually pick up solid debris. The actual worksite is an area which had several tanks or pits. The pits were of different configurations: there were rectangular, square as well as round pits, varying in depth from 15 to 30 ft. While the pits were separated by concrete walls, they were connected together at the bottom but were guarded by gates. After coming out of a 15 ft pit, Employee #1 was resting on the perimeter of the pits, preparing to enter into a 30 ft pit. He was wearing a body harness with a lanyard. Employee #1 was a six foot tripod, an emergency rescue equipment, leaning against a post. Upon seeing that his coworkers were having difficulty setting up a ladder for the next descend, Employee #1 walked across the top of the walls of the pits to help Employee #2 and Employee #3 out. As he walked across, employee #1, somehow pulled the tripod with him, the tripod fell and dropped into one of the pits, pulling him down with it. Before Employee #1 fell into the hole, his head hit the lip of the 29-in. wide pit, causing him to die of blunt head trauma. It is not clear whether his landyard got entangled with the tripod or that Employee #1 had hooked both his lanyard caribeeners into the tripod. According to refinery management, when the tripod was retrieved out of the pit, both caribeeners of the lanyard of Employee #1 were found hooked up to the tripod.

Keywords: HEAD, LADDER, LANYARD, PIT, FALL, TANK
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery Maintenance or repair Under $50,000 15 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 305479610 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 15 feet
Cause: Dredging
Fatality Cause: Fall through opening (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.