Accident Report Detail
Accident Summary Nr: 201036894 - Pipe Falls and Crushes Employee's Fingers
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 305478034 | 02/02/2005 | 7363 | 561320 | Contractor'S Employment Services Inc |
Abstract: On January 24, 2005, a welder, Employee #1 was moving a 17-ton I-beam. Employee #1 and Employee #2 (forklift driver) were moving the 46-in.-high and 50-ft-long I-beam. Two 3-in., schedule-120 carbon steel pipes were positioned under the beam to allow it to roll. As the I-beam rolled forward, Employee #1 repositioned the pipes from the rear of the beam to the front. At the time of the accident, Employee #1 motioned to Employee #2 to stop the forklift so he could remove one length of the pipe. As Employee #1 pulled the pipe from under the I-beam, the beam rolled forward forcing the pipe to the ground. Employee #1's right hand was underneath it, causing a crushing injury to his right hand. Two of his fingers were amputated, and his ring finger was partially amputated. The accident occurred in a 1-acre staging area of a metal recycling facility, where beams were cut and sometimes welded together for future use.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 305478034 | Hospitalized injury | Amputation | Welders and cutters |