Accident Summary Nr: 201036498 - Employee Suffers Amputation When Finger Caught in Sprocket

Accident Summary Nr: 201036498 -- Report ID: 0950635 -- Event Date: 09/10/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
12022666710/07/20042653322211International Paper

Abstract: On September 10, 2004, Employee #1 was working at a facility used for the manufacture of corrugated container boxes. Many semi-finished or rejected boxes were compressed and strapped into bales in a baling machine and moved out through powered conveyors. The accident happened near a chain-sprocket drive system which powers the conveyor of baling machine Number1. The baling machine has a panel with an emergency stop and two interrupter switches (for the conveyor line involved in the accident). The conveyor line became jammed due to a protruding wire next to a sprocket (which powers the conveyor rollers). Employee #1, the baling machine operator pressed both interrupter switches before he proceeded to pull out the wire from the conveyor line. When Employee #1 pressed the switches he did not fully engage them. In such cases, the conveyor line stops but if a person goes near the conveyor the photo cell picks up a signal and the conveyor starts again. As Employee #1 came near the affected conveyor sprocket, the photo cell activated the line again and the conveyor sprocket started moving just as Employee #1 used his right hand to pick up the wire next to the sprocket. Employee #1's right third finger tip (along with the hand glove) was caught at the nip point of the chain sprocket. Employee #1 instantly pulled his hand out but the glove remained at the nip point. As the hand (without glove) was withdrawn, Employee #1 became aware of the amputation of the finger. If Employee #1 had activated the two switches completely, the sensor would not have activated the roller. The employer's procedure is to lockout and tag out the system in order to remove a jam on the conveyor line. Employee #1 was hospitalized.

Keywords: AMPUTATED, FINGER, CAUGHT BY, EMERGENCY STOP, JAMMED, LOCKOUT, BALER, CONVEYOR, SPROCKET, NIP POINT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120226667 Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close