Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201036340 - Employee burned when vapors ignite during welding

Accident Summary Nr: 201036340 -- Report ID: 0950635 -- Event Date: 05/20/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30547712709/14/20041629237120Matrix Service Inc

Abstract: On May 20, 2004, Employee #1, a welder, and a coworker-helper were working for a mechanical contractor at a refinery. At 7:00 a.m., a hot work permit, Number 420446, had been issued for hot work on the Number #1 Lift Station Oil Trap-Whole Bay. At approximately 11:00 a.m., another of the contractor's work crews removed an air blower from an overflow pit adjacent to the oil trap and placed metal covers over the top of the overflow pit. The air blower had been used to keep hydrocarbon vapors from backing up into the overflow box. About two hours later, this same work crew anchored a come-along to a valve box and used it to move one of the metal covers into place. This valve box was bolted to the metal plate sitting on the northern half of the overflow pit. Anchoring the come-along to the valve box caused the plate holding the valve box to flex, breaking the vapor seal along the north side of the plate. Despite these two changes in the conditions adjacent to the southeast corner of the lift station oil trap, the hot work permit was not terminated. At approximately 3:46 p.m., a coworker was using a cutting torch to cut a diamond plate adjacent to the northwest corner of the overflow pit. Employee #1 was setting up to weld north of the coworker-helper. The torch operator was east of the coworker-helper and was attempting to fight a fire when he noticed material burning next to the cutting operation. At that time, the hydrocarbon vapors ignited and a flash of flames shot out from under the plate covering the north side of the overflow pit. Employee #1 sustained second-drgree burns to the left side of his face, for which he was hospitalized for five days. The coworker-helper suffered second-degree burns to small areas on his left hand and on the back of his left leg. He was trabsposted to the hospital, where he was treated and released. It was later determined that the coworker-helper's coveralls looked like they were made of fire retardant material, but were not.

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, PPE, WORK RULES, FIRE, CONSTRUCTION, WELDING, FACE, REFINERY
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery Alteration or rehabilitation Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 305477127 Hospitalized injury Burn/Scald(Heat) Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Post Decking Detail Work
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.