Accident Summary Nr: 201036241 - Employee Injures Foot When Struck by Falling Object

Accident Summary Nr: 201036241 -- Report ID: 0950635 -- Event Date: 05/18/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30547676408/13/20049199921190La Cnty Dept Of Public Works; Flood Maint Div

Abstract: At approximately 5:15 p.m. on May 18, 2004, Employee #1 and other coworkers were renovating a water well. Following the barrier crew pipefitting work, Employee #1 pumped water out of the well cellar. The driller crew then positioned a hook of a 15-ton crane over the center of the well head. The crane involved was a Terex Stinger truck mounted crane, Model No. BT-3063, serial number 4510102088. Employee #1 was standing at the far edge of the cellar from where the crane stood. The crane had a main and an auxiliary hoist line. When the crane operator extended the boom, the auxiliary hoist line snapped, causing the crane's ball and hook to fall. They fell, striking Employee #1's left foot and amputating his fourth and fifth toes He was wearing steel-toed rubber boots. The auxiliary hoist line had an anti two-block device on it, but it failed to work. The anti two-block device was visually checked, prior to operating the crane that day. However, it was not actually tested to see whether it functioned properly or not.

Keywords: CRANE BALL, AMPUTATED, CRANE HOOK, HOIST, OVERHEAD CRANE, STRUCK BY, TOE, TWO-BLOCKING, FALLING OBJECT, FOOT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305476764 Hospitalized injury Amputation Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close