Accident Summary Nr: 201033941 - Employee Suffers Amputation Of Finger

Accident Summary Nr: 201033941 -- Report ID: 0950635 -- Event Date: 09/30/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30076239010/30/200179330Gable House Bowling

Abstract: Several bowling balls had jammed on the ball return. This caused the motor to overheat and stop and the belt to dislodge. Employee #1, a maintenance mechanic, retrieved the jammed balls, but did not deenergize the motor prior to his repositioning of the belt. Employee #1 started to reposition the V-belt, but as he was positioning the final loop on the belt, the motor, belt and wheels moved, pulling his hand into the in-running nip-point of the upper pulley wheel. Employee suffered the amputation of his left ring finger as it was caught in an in-running nip- point between a v-belt and a pulley wheel of the ball lift assembly. Employee #1 was hospitalized.

Keywords: AMPUTATED, FINGER, LOCKOUT, V-BELT, NIP POINT, PULLEY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300762390 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close