Accident Summary Nr: 201030681 - Employee's arm injured when struck by falling forklift mast

Accident Summary Nr: 201030681 -- Report ID: 0950635 -- Event Date: 04/24/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12029641305/27/199733120Paramount Forge

Abstract: Employee #1, a maintenance man for a metal forging plant, was repairing a Hyster H-60 forklift, serial #C5D3772H, with the help of coworkers from shipping and receiving. The chain had fallen off its track and the forklift mast was stuck on the second of its three stages. Employee #1 climbed onto the lift and asked a coworker to block it. A coworker placed a 4 by 6 piece of lumber underneath the forks and then called up to say that this had been done. Employee #1 began working from the side opposite the forks, putting his arm through the mast. As he freed the chain and mast, the mast came down, crushing his left arm. The equipment being repaired was not effectively blocked to prevent movement.

Keywords: CHOCK, MAINTENANCE, REPAIR, UNSECURED, BLOCKS, WORK RULES, CRUSHED, INDUSTRIAL TRUCK, ARM, COMMUNICATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120296413 Hospitalized injury Fracture Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close