Accident Summary Nr: 201030673 - Nine employees exposed to benzene

Accident Summary Nr: 201030673 -- Report ID: 0950635 -- Event Date: 02/15/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12029595102/28/199729110Mobil Oil Corp

Abstract: On February 14, 1997, during the shutdown/turnaround period for an unsaturated gas plant, Delta Tech, the contractor, completed a water/chemical wash of debutanizer tower 8C-6 and heat exchanger 8E-39. At approximately 8:05 a.m. on February 15, 1997, Employee #1 was requested by the control room of the unsaturated gas plant to drain any water/chemical residues from heat exchanger 8E-39. Employee #1 drained the material through the heat exchanger's bottom drain valve into the refinery's sewer. As the residue was released, it changed into gasoline. Once the supervisor took notice of the gasoline, he attempted to close the bottom drain valve. The valve bushing broke and Employee #1 notified maintenance that assistance was needed to close the valve. Maintenance responded by putting in a sipe valve and tapping it into packing. Mobil's fire brigade and its safety and emergency response team brigade were notified and barricade the immediate area around the debutanizer and heat exchanger. Industrial hygienists monitored the perimeter and sewer system for benzene, with results indicating levels between 1.9 and 11.6 benzene. Employees #1 through #9 were taken to a medical clinic for benzene testing. Urinary phenol evaluations indicated levels that did not require additional testing.

Keywords: BENZENE, WORK RULES, TOXIC ATMOSPHERE, INHALATION, AIR CONTAMINATION, CHEMICAL REACTION, CHEMICAL VAPOR, TOXIC FUMES, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
2 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
3 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
4 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
5 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
6 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
7 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
8 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
9 120295951 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.