Accident Summary Nr: 201030483 - Employee injured in fall through roof opening

Accident Summary Nr: 201030483 -- Report ID: 0950635 -- Event Date: 01/20/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12029577901/31/199795110Cst Environmental

Abstract: At approximately 8:00 a.m. on January 20, 1997, Employee #1 and a coworker, both asbestos field technicians for CST Environmental, were working on the roof of a vacant 25 ft tall building in Lakewood, CA. The house was being demolished and first had to undergo asbestos removal. On the previous afternoon, the coworker had cut a 38 in. square hole in the roof to install a chute, covering it with a 3/4 in. piece of plywood cut to the appropriate size and held in place with a sandbag. He also erected two, 5 ft tall scaffold sections on opposite sides of the hole; the remaining sides had crossbraces tied to the scaffold sections. On the morning of January 20, the coworker removed the sandbag and asked Employee #1, who had not seen the hole preparations the previous day, to remove the cover. He picked up the plywood and walked straight into the hole. Employee #1 was transported to Long Beach Memorial Medical Center. When the DOSH compliance officer visited him in the hospital, he was not able to talk and he did not seem to remember things. Causal factors in this accident include (1) the hole opening not being guarded by a standard railing and the cover not being well-secured and clearly labeled OPENING--DO NOT REMOVE; and (2) failure to use approved safety belts and lanyards. The supervisor who had been overseeing operations at the site, was on the ground at the time of the accident.

Keywords: ROOF OPENING COVER, GUARDRAIL, UNSECURED, UNSECURED PANEL, WORK RULES, FALL, FALL PROTECTION, ROOF OPENING, INATTENTION, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120295779 Hospitalized injury Dislocation Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close