Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201022100 - Employee's Hand Is Crushed by Shifting Load

Accident Summary Nr: 201022100 -- Report ID: 0950615 -- Event Date: 01/27/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
12554134201/28/20093565333993Interflex Llc

Abstract: On January 27, 2009, Employee #1, with Interflex, LLC., (a full-service designer and manufacturer supporting the printing and converting industries), was installing a Web-Fed rotary UV/Aqueous coater and a rotary die cutter on a Sanjo press for Ben Franklin Press. While removing a label from the anvil roll of the press, Employee #1's hand was located under a load suspended load from a forklift. When the load shifted, his right hand was crushed between the anvil roll and the suspended magnetic die roll, which weighed approximately 1,000 lbs. Employee #1 was hospitalized for treatment.

Keywords: DIE, PRINTING PRESS, PRINTING, LOAD SHIFT, SUSPENDED LOAD, ROLLER--MACH/PART, CAUGHT BETWEEN, CRUSHED, HAND, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125541342 Hospitalized injury Bruise/Contus/Abras Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close