Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201020989 - Employee Falls from Scissor Lift, Sustains Injuries

Accident Summary Nr: 201020989 -- Report ID: 0950615 -- Event Date: 08/17/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
12553362008/17/20061731238210Barnum & Celillo Electric Inc

Abstract: At approximately 1:00 p.m. on August 17, 2006, Employee #1 was driving a JLG brand scissors lift (model number m2630 ES, serial number 0200125224), over a floor opening. The opening was covered with a sheet of one half inch, 5-ply, plywood. The plywood had an APA Span Rating of 32/16, with a maximum live load rating of 70 lbs. for a 24 in. span. The floor opening was in a concrete slab floor with hole dimensions of 36 in by 32 in by 10 in depth. The employee ran over the plywood with a wheel of the scissor lift. The plywood broke and the forklift tipped over. The employee fell with the vehicle until he struck the concrete floor. He was taken by ambulance to Santa Rosa Memorial Hospital. Employee #1 sustained a fractured right ankle and a head injury and was hospitalized for three days. It was determined that a contributing factor to the accident was that there was not adequate cover over the floor opening.

Keywords: FRACTURE, HEAD, HYDRAULIC LIFT, ROLL-OVER, STRUCK AGAINST, FALL, AERIAL LIFT, ANKLE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Alteration or rehabilitation $500,000 to $1,000,000 1

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125533620 Hospitalized injury Fracture Electricians Distance of Fall: feet
Worker Height Above Ground/Floor: 8 feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Fall from vehicle (vehicle/construction equipment)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close