Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201010295 - Employee Is Injured in Fall Through Hole in Roof

Accident Summary Nr: 201010295 -- Report ID: 0950661 -- Event Date: 06/02/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31526834207/13/20111711238220Ram Mechanical Inc

Abstract: At approximately 1:30 p.m. On June 2, 2011, Employee #1, of Ram Mechanical Inc., a licensed General Contractor, was installing an exhaust fan on the roof of the main production building at Peninsula Plastics Recycling Inc. Employee #1 and Employee #2 were in the process of installing an exhaust fan through the metal roof of the Production building at Peninsula Plastics Recycling Inc. The steel building was approximately 100 feet wide by 400 feet long. The roof was made of 18 gauge galvanized sheet metal and has a slope of 1:12. The hole being cut was at the approximate center of the structure. The peak of the roof was approximately 35 feet above floor level. Employee #1 was using a 4 inch right angle grinder with a cut-off wheel to cut the roofing metal. Employee #1 had made cuts on three sides of the intended hole of approximately 42 inches per side. Employee #1 had left "holding" metal on each cut side to support the metal and prevent it from falling through as the final cut was being made. Employee #1 repositioned himself for the final cut. As he started making the cut he inadvertently placed weight on the cut portion of the metal roofing causing it to give way. He fell through the opening head first. Employee #1 landed on a conveyor approximately 15 feet below the opening. Employee #1 sustained fractures to three thoracic vertebrae with fractures to the adjacent ribs and a laceration to the scalp. Employee #1 was transported by ambulance to the Emanuel Medical Center in Turlock; he was hospitalized for three days. The accident was caused by the employee inadvertently placing weight onto the already partially cut portion of the roof metal which subsequently gave way. Employee #3, the Office Manager for Ram Mechanical Inc. reported the injury to the Modesto District Office on June 2, 2011 at 1:30 p.m. A second notification was received by the Modesto District Office from the Turlock Police/Fire Dispatch on June 2, 2011 at 1:50 p.m. The reporting requirements were met. The HHU received the information on the accident from the Modesto District Office on July 12, 2011 and an inspection was opened on July 13, 2011.

Keywords: FRACTURE, HEAD, ROOF, WARNING LINE, FLOOR HOLE, LACERATION, RIB, FALL, FALL PROTECTION, VERTEBRA
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Alteration or rehabilitation Under $50,000 1 30

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 315268342 Hospitalized injury Fracture Sheetmetal duct installers Distance of Fall: feet
Worker Height Above Ground/Floor: 31 feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close