Accident Report Detail
Accident Summary Nr: 200998474 - Five Employees Are over Exposed to Carbon Monoxide
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
314740002 | 11/11/2010 | 8361 | 623990 | Gibson County Area Rehabilitation Centers, Inc. |
Abstract: On November 11, 2010, five employees of Gibson County Area Rehabilitation Centers, Incorporated, were working in or near the Industrial Services Area on a forklift. The combination of operating an improperly maintained forklift, inside an area with little to no air ventilation, caused all the employees to be exposed to vast concentrations of carbon monoxide (CO). Two of the five employees lost consciousness while working in the Industrial Services Area. All of the employees were transported to Gibson General Hospital, where blood draws were taken to determine each employee's blood gas levels, including the percentage of carboxyhemoglobin (COHb) present in each employee's blood. It was determined that the employees had COHb levels, ranging between 6.1 and 23.3. All five of these employees were diagnosed with CO toxicity/poisoning. They were given 100 percent oxygen for several hours to lower their COHb blood levels and kept overnight for observation.
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 314740002 | Hospitalized injury | Poisoning(Systemic) | Assemblers | ||
2 | 314740002 | Hospitalized injury | Poisoning(Systemic) | Janitors and cleaners | ||
3 | 314740002 | Hospitalized injury | Poisoning(Systemic) | Assemblers | ||
4 | 314740002 | Hospitalized injury | Poisoning(Systemic) | Assemblers | ||
5 | 314740002 | Hospitalized injury | Poisoning(Systemic) | Assemblers |