Accident Summary Nr: 200996593 - Employee Is Killed from Inhalation of Solvent

Accident Summary Nr: 200996593 -- Report ID: 0551800 -- Event Date: 03/27/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31126153105/05/20081793238150True Finish Electrostatic Painting Reglazing, Inc.

Abstract: Employee #1 was using a paint stripper, which contained approximately 75-100% methylene chloride to remove paint from a bathtub. A coworker found Employee #1 on his knees face down leaning on the bathtub. A very strong chemical odor was present in the bathroom. Employee #1 died due to asphyxiation to the central nervous system.

Keywords: ENCLOSED SPACE, ASPHYXIATED, CONFINED SPACE, METHYLENE CHLORIDE, INHALATION, PAINT SOLVENT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Alteration or rehabilitation Under $50,000 2 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311261531 Fatality Asphyxia Supervisors; painters, paperhangers and plasterers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.