Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200980910 - Drill Rig Worker Is Killed When Struck by Discharge Hose

Accident Summary Nr: 200980910 -- Report ID: 0855610 -- Event Date: 12/29/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30950114601/02/20081389213112Trecoby Services Llc

Abstract: On December 29, 2007, a three-person rig crew was working to unload water from a well casing using a drilling rig and a discharge line. The second rig hand opened a ball valve on the compressor, creating air pressure through the compressor, down the tubing, and into the well casing. The first rig hand stepped over the discharge line just as pressure caused the line to buck and free itself from the metal posts and chain holding it in place on the ground. The discharge line spun into the air, striking the first rig hand in the head. He subsequently collapsed under the drilling rig. The second rig hand administered cardio-pulmonary resuscitation to the injured worker, while the driller went up a nearby hill to obtain mobile phone reception and call for medical help. The injured worker was pronounced dead on the scene.

Keywords: AIR PRESSURE, HEAD, UNSECURED, WELL, COMPRESSED AIR, WATER HOSE, STRUCK BY, OIL RIG, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309501146 Fatality Puncture Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close