Accident Summary Nr: 200980803 - Employee Killed When Scaffold Falls

Accident Summary Nr: 200980803 -- Report ID: 0855610 -- Event Date: 03/20/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30949788103/20/20071799236220Irwin Industries Inc

Abstract: On March 20, 2007, Employee #1, along with other employees, was working in a boiler at a power plant. They were removing heat exchange tubing in the throat area of a boiler. The tubing was supporting the scaffold in the throat area. When the tubing was cut and removed from its normal location, the scaffold support was no longer secure and a portion of it fell into the bottom of the boiler. Employee #1, who was standing on the scaffold, fell with it to the bottom, and was killed.

Keywords: HEAD, DISMANTLING, UNSECURED, BOILER, CONSTRUCTION, FALL, CUTTING AND BURNING, SCAFFOLD, UNSTABLE POSITION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant Maintenance or repair $250,000 to $500,000 6 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 309497881 Fatality Other Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: 25 feet
Cause: Demolition
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.