Accident Summary Nr: 200980795 - Employee Is Electrocuted While Working on Generator

Accident Summary Nr: 200980795 -- Report ID: 0855610 -- Event Date: 02/19/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30949782402/20/20071381213111Sst Energy Corporation

Abstract: On February 19, 2007, Employee #1, a floor hand, was cleaning the Number 2 diesel powered generator. He was using a wire brush to clean the steel grating that covered the rear section of the generator. He came in contact with an energized electrical cable that was located directly below the generator that powered the radiator fan motor for the diesel engine. Employee #1 was electrocuted.

Keywords: ELECTRIC CABLE, CLEANING, ELECTROCUTED, STRUCK AGAINST, LOCKOUT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309497824 Fatality Electric Shock Helpers, extractive occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.