Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200980209 - electric shock - contact with overhead line thru boom

Accident Summary Nr: 200980209 -- Report ID: 0855610 -- Event Date: 02/14/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30071200702/14/200016230Okemah Construction

Abstract: Two employees were using a Caterpillar 561C sideboom to unload pipe from a truck. The boom was 8.5 meters long. A cable on the sideboom contacted an overhead power line, electrocuting both employees.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E C, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300712007 Fatality Electric Shock Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electrocution by equipment contacting wire
2 300712007 Fatality Electric Shock Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close