Accident Summary Nr: 200968469 - Employee's right arm amputated after injury in rollers

Accident Summary Nr: 200968469 -- Report ID: 0352440 -- Event Date: 07/19/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30354576807/19/200022990Tedco Industries, Inc.

Abstract: At approximately 4:30 p.m. on July 19, 2000, Employee #1 was repairing or resetting two chains that had come off their sprockets underneath the #3 garnett line. He crawled under the line into a 2 ft tall by 5 ft wide space with teethed rollers above him and a 6 in. diameter auger rotating at 1,160 rpm. While Employee #1 was under the line, the coworker foreman turned on the doffer roller switch. After crawling past the spinning auger, Employee #1's flannel shirt collar became snagged by one of the doffer rollers. He raised up his right arm reflexively, and it became caught between two teethed rollers. His right arm was mangled in the nip point between the rollers and had to be surgically amputated above the elbow. The motors controlling the doffer rollers had been turned off, but the machine was not locked out or tagged out.

Keywords: CLOTHING, AMPUTATED, REPAIR, WORK RULES, CAUGHT BY, LOCKOUT, ROLLER--MACH/PART, CAUGHT BETWEEN, SPROCKET, ARM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303545768 Hospitalized injury Amputation Miscellaneous textile machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close