Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200967347 - Employee killed when flammable gases explode

Accident Summary Nr: 200967347 -- Report ID: 0352470 -- Event Date: 06/25/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30349152606/26/200076920Brownies Welding, Fabricating And Compactor Servic

Abstract: Employee #1, the president of the company, was at the work site when apparently some compressed oxygen was released in the presence of acetylene gas or some other fuel. An explosion occurred and he was killed. This was a sole proprietorship, and there were no other employees present at the time of the accident.

Keywords: OXYGEN, VAPOR, FLAMMABLE VAPORS, ACETYLENE, WORK RULES, COMPRESSED GAS, FIRE, EXPLOSION, CHEMICAL REACTION, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303491526 Fatality Burn/Scald(Heat) Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close