Accident Report Detail

Accident Summary Nr: 200966547 - Employee killed when run over by dump truck

Accident Summary Nr: 200966547 -- Report ID: 0352410 -- Event Date: 08/17/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30392906108/17/200015410J. Edward Powell

Abstract: On August 17, 2000, a 20-ft by 500-ft steel strand building was under construction. Drain pipes were being installed along the perimeter of the inside of the building and fill dirt was being brought in to fill around the foundation walls after the pipe was installed. A 1977 Ford tandem axle dump truck was being used to bring in the fill dirt. One load of fill dirt had been delivered. The driver returned with a second load and backed down the right center on the northern side of the building. After backing approximately two-thirds the length of the building, Employee #1 stopped the truck and told the driver that he was backing into a soft area. Employee #1 told the driver that he wanted the truck to back through the center of the building to the southern side and dump the dirt. The truck then backed through two support poles as Employee #1 directed the truck back from the driver's side. The driver stated that he had Employee #1 in the driver's mirror as he backed through the first set of Poles. When he backed to the next set of poles he lost sight of Employee #1. Employee #1 had walked behind the back of the moving truck. The driver continued to back up and started looking at the two pole. When the back of the truck cleared the poles he was told to stop the truck. He stopped the truck and saw that he had run over Employee #1 who was lying on his back, between the tandem tires with one arm under a tire. Employee #1 died.

Keywords: PINNED, STRUCK AGAINST, CRUSHED, TRUCK, DUMP TRUCK, STRUCK BY, RUN OVER, TRUCK DRIVER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 1 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303929061 Fatality Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Backfilling and compacting
Fatality Cause: Crushed/run-over by highway vehicle

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.