30279761801/11/200017990Lindstrom Excavating Contractors Inc

Abstract: A two man crew consisting of an equipment operator/crew leader and Employee #1, a laborer, were in the process of unloading 2 ft by 2 ft by 8 ft concrete blocks from the back of a dump truck. A CAT 225 BLC tracked excavator hoe was used for craning the blocks from the bucket hook attachment using a sling made of chains. The accident occurred when one of the blocks, that weighed approximately 4600 lbs, had been raised off the truck bed and after passing more than halfway off the end of the truck, had the short loop section of chain attached to the hoe bucket break causing the block to fall. Employee #1, who had been performing the rigging work up on the truck bed, was in close proximity to the block at this time. When the block dropped, Employee #1 fell from the truck or block and ultimately ended up prone, landing face first on the ground. The block landed on its end beside him and then fell on its side, across his lower legs. Employee #1 had his left lower leg amputated with severe injuries to the lower right leg. Examination of the broken chain sling pieces, showed one broken link, wearing and stretching of other links, open fractures in additional links were also noted. The employer did not perform competent person sling inspections. Hazard recognition training was not provided to employees using the rigging equipment. The chains in use were not tagged to identified, no tags lines were used.

Keywords: CHAIN, BLOCKS, TRUCK, DUMP TRUCK, BROKEN CHAIN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Shoreline development, dam, reservoir New project or new addition Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302797618 Hospitalized injury Fracture Helpers, construction trades Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Seawall construction, riprap placement
Fatality Cause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.