Accident Summary Nr: 200963130 - Employee killed when struck by bridge piling during loading

Accident Summary Nr: 200963130 -- Report ID: 0352420 -- Event Date: 07/28/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30288342607/28/199916220The Six M Company, Inc.

Abstract: Employee #1, a truck driver for Crouse Construction, Inc., was preparing to use a 30 ft demolition trailer to haul away 18 ft to 20 ft long bridge pilings from a work site. Coworkers from Six M Construction, Inc., were rigging them to a 70-ton American crawler crane and loading them onto Employee #1's trailer. As the boom was being lowered to the trailer with the first load, the load line was raised and the two Six M coworkers standing at the rear of the trailer were signaling to the crane operator. At one point during the lift, the suspended load extended between 3 and 4 ft beyond the back end of the trailer, and Employee #1 climbed to a platform at the front of the trailer and began waving his arm in a "come on" motion to the crane operator. At this time, the load, which was unbalanced, became caught on either the rear side or the rear floor edge of the trailer and suddenly shifted with a pendulum motion. It moved rapidly forward, striking Employee #1 in the face and neck and knocking him 9 ft 6 in. to the ground. He died of multiple head and neck trauma. The Six M Construction Company was cited for apparent violations of 29 CFR 1926.550(a)(4) and 29 CFR 1926.550(b)(2).

Keywords: LOADING, HEAD, CRAWLER CRANE, LOAD SHIFT, CAUGHT BY, CONSTRUCTION, NECK, STRUCK BY, FLYING OBJECT, UNSTABLE LOAD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge Alteration or rehabilitation $1,000,000 to $5,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302883426 Fatality Concussion Truck drivers, heavy Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.