Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200962504 - Employee falls and dislocates his shoulder

Accident Summary Nr: 200962504 -- Report ID: 0352420 -- Event Date: 10/06/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30246310410/06/199817990American Platform & Scaffolding Inc

Abstract: Employee #1 falls from work surface dislocating his shoulder and is hospitalized.

Keywords: SHOULDER, DISLOCATED, FALL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 7

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302463104 Hospitalized injury Dislocation Truck drivers, light Distance of Fall: feet
Worker Height Above Ground/Floor: 14 feet
Cause:
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close