Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200962397 - Employee injured when struck by crane load

Accident Summary Nr: 200962397 -- Report ID: 0352410 -- Event Date: 07/22/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30202515007/22/199816220James Julian, Inc. Of Delaware

Abstract: A crane operator and Employee #1 were off-loading four concrete deadman blocks from a lowboy trailer, one at a time. The blocks were about 4 ft by 4 ft by 3 ft, and each weighed about 6,200 lb. The friction clutch crane was a 1959 Northwestern 80D, crawler mounted, with a 70 ft lattice boom. After the hoist line was attached to the last of the blocks, the operator took tension. Employee #1 gave the hand signal to raise, then moved further out beside the block. The block had been raised just off the trailer deck when the crane swung unexpectedly to the operator's left and the block struck Employee #1, driving her into the exposed tops of the rear axles. Her right leg was amputated, her left leg sustained crushing injuries, and she also suffered head trauma. The crane was not positioned on a level surface. The load swing during the accident was toward the low side--which was the direction of the planned swing, but the operator stated that the swing occurred before he planned to release the manual swing brake. Witnesses stated that the swing brake was found to be engaged following the accident. The swing brake was found to be functioning when tested in a limited test following the accident; no under load or additional test was performed due to the unknown condition of, and damage to, the crane. Non-accident-related violations included damaged boom lacing, no auto boom stop, no swing radius guarding, and no inspection by a competent person.

Keywords: HEAD, AMPUTATED, CRAWLER CRANE, SUSPENDED LOAD, CONSTRUCTION, MECH MAT HANDLING, OFF LOADING, STRUCK BY, SLOPE, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Alteration or rehabilitation $1,000,000 to $5,000,000 30

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302025150 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Forming
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.