Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200960888 - Employee injured in fall down mechanical shaft

Accident Summary Nr: 200960888 -- Report ID: 0352430 -- Event Date: 03/19/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12738163003/19/199717110J. William Parker & Son, Inc.

Abstract: Employee #1, a second-year plumbing apprentice, was helping his employer install a hot water pipe on the fourth floor of an addition being constructed at the headquarters of the Baltimore Police Department. His employer had asked him to get a sighting on the pipe, which ran in a north-south direction across the ceiling and into an area protected by a wire rope guardrail system. The guarded area consisted of a men's lavatory, three elevator shafts, and a mechanical shaft. The hot water pipe, which was one of three pipes that Employee #1 and his employer were to install, protruded approximately 12 to 18 in. into the guarded area. When Employee #1 entered the guarded area to sight the pipe, his employer was already in it, working on the pipe in the area's north side. The employer later said that Employee #1 was in plain view as he entered the guarded area. In the process of siting the hot water pipe, Employee #1 walked backwards in a southerly direction, and fell through the 32 in. wide by 64 in. long hole in the cross-bracing of the mechanical shaft. He fell 48 ft and landed on some steel pipes at the bottom of the shaft. Employee #1 sustained a concussion, a fractured knee, and a lacerated liver, and was taken by ambulance to the Maryland Shock Trauma unit. His employer's foreman later stated that plumbers are responsible for the apprentices working under them. Although the employer has a policy of using fall protection 100 percent of the time, it was not consistently enforced, and violations were not documented. Employee #1 was not using any form of fall protection at the time of the accident.

Keywords: INSTALLING, WORK RULES, CONSTRUCTION, LIVER, SHAFT, FALL, FALL PROTECTION, PLUMBING, CONCUSSION, WALKING BACKWARD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $5,000,000 to $20,000,000 5

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 127381630 Hospitalized injury Concussion Plumber, pipefitter and steamfiter apprentices Distance of Fall: feet
Worker Height Above Ground/Floor: 48 feet
Cause: Interior plumbing, ducting, electrical work
Fatality Cause: Fall through opening (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.