Accident: 200960268 - Employee Injured When Aerial Lift Overturned

Accident: 200960268 -- Report ID: 0352440 -- Event Date: 10/02/1996
InspectionOpen DateSICEstablishment Name
12737323110/02/19960783Scott Service Corporation

An employee was trimming trees from an overhead power line. He was at a height of between 2.4 and 3.7 meters above the ground, wearing a full body harness and shock-absorbing lanyard attached to the bucket of an aerial lift. The aerial lift's left-side outrigger was stable and set up on the roadway. The right-side outrigger was resting on two 660-millimeter by 620-millimeter wooden pads lying on soft, wet soil at the edge of the roadway. The pads and outrigger sank in the soft earth, causing the truck to lean over and the bucket to drop until it struck the ground. The employee was ejected from the bucket onto the ground, injuring his neck and back. He was hospitalized for his injuries. The site supervisor had positioned and set up the aerial lift truck.

Keywords: fracture, outrigger, elec utility work, fall, vertebra, tree trimming, aerial lift, overturn

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 127373231 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close