Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200940062 - Employee killed when compactor rolls over

Accident Summary Nr: 200940062 -- Report ID: 0625100 -- Event Date: 10/18/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30067507110/20/199991990Heavy Construction Unit, Navajo Region, Bia

Abstract: Employee #1 was backing a Bross compactor, model 4000, in third gear down the road and away from a work site. He had started to veer off the road when his inside tire struck a rock that stuck up about 8 in. above the road surface. This caused the compactor to flip upside down, crushing and killing Employee #1. He had been wearing his seat belt, but the compactor had no ROPS.

Keywords: UNEVEN GROUND, ROLLER--CONST EQUIP, WORK RULES, EQUIPMENT OPERATOR, ROPS, STRUCK AGAINST, DRIVER, EARTHMOVING EQUIP, BACKING UP, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300675071 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.