Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200924652 - Employee Is Killed by Paper Baler

Accident Summary Nr: 200924652 -- Report ID: 0355111 -- Event Date: 11/17/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
31054354111/17/20062653322211Richmond Corrugated Box Company

Abstract: At approximately 12:30 p.m. on November 17, 2006, Employee #1 accessed the manhole door above the paper baler, by standing on a pallet that was raised on a forklift. He opened the manhole door and went into the baler. He was killed when the electric eye sensed him, like paper that had fallen from the cyclone, and cycled the baler.

Keywords: BALER DOOR, WORK RULES, INDUSTRIAL TRUCK, BALER, PALLET, ELEVATED WORK PLAT, HOPPER, MACHINE--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310543541 Fatality Amputation Miscellaneous machine operators, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.