Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200922763 - Employee Is Killed by Electric Shock

Accident Summary Nr: 200922763 -- Report ID: 0355116 -- Event Date: 10/13/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31607203210/13/20110783561730Asplundh Tree Expert Co

Abstract: On October 13, 2011, Employee #1 was trimming trees on the south side of the road from an insulated bucket truck, using a hydraulic saw blade. A tree from the north side fell onto the primary overhead power line on the south side. The power line moved in a downward motion, striking Employee #1 in his lower back, causing his face to strike the neutral line. He received an electrical shock and was killed.

Keywords: TREE LIMB, ELECTROCUTED, STRUCK AGAINST, SAW, ELECTRIC SHOCK, STRUCK BY, FACE, FALLING OBJECT, TREE TRIMMING, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316072032 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.