Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200920072 - Employee killed when struck by backing dump truck

Accident Summary Nr: 200920072 -- Report ID: 0355114 -- Event Date: 05/20/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
12547111005/21/199816110General Excavation Inc.

Abstract: Employee #1 was walking in the middle of a two-lane roadway under construction while a coworker was operating an off-road dump truck, compacting the soil. The truck was backing up when he was struck by its right rear tires. Employee #1 was killed. The driver did not see him and the truck's reverse signal alarm was not working at the time of the accident.

Keywords: BACK-UP ALARM, HIGHWAY, SIGNALMAN, CONSTRUCTION, EARTHMOVING EQUIP, TRUCK, DUMP TRUCK, BACKING UP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Maintenance or repair $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125471110 Fatality Fracture Operating engineers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Backfilling and compacting
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.