Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200902138 - Workers Injured, Killed in Combustible Sugar Dust Explosion

Accident Summary Nr: 200902138 -- Report ID: 0418400 -- Event Date: 02/07/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31098884502/10/20087349561790Stokes Contracting, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098883702/10/20087349561790Kerby Enterprises, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098871202/10/20082062311312Imperial Sugar Company; Imperial-Savannah, L.P.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098883702/10/20087349561790Kerby Enterprises, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098884502/10/20087349561790Stokes Contracting, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098871202/10/20082062311312Imperial Sugar Company; Imperial-Savannah, L.P.
Inspection NrDate OpenedSICNAICSEstablishment Name
31098884502/10/20087349561790Stokes Contracting, Inc.

Abstract: At approximately 7:16 p. m. on February 7, 2008, an explosion and fire occurred at the Imperial Sugar Company (doing business as Imperial-Savannah, L.P. or Savannah Food & Industries, Inc.) sugar refinery site in Port Wentworth, GA. The first 911 call was received at approximately 7:17 p.m., while the initial response by local fire and police was initiated at approximately 7:20 p.m. The force of the explosion destroyed or affected three silos 32 meters tall by 12.2 meters in diameter (105 feet tall by 40 feet in diameter) containing refined granulated sugar and the four-story packing houses surrounding the North, South, and East sides of the silos. In addition, heavy fire and/or blast damage was sustained in portions of the refinery area of the plant (East side of the South Packing House), the Palletizing Area (West of packing house), the G.O. Shop/Laboratory/Hog Room building (East of Bosch Packing House), and the Bulk Sugar Building and "J-Bin, which are separate structures from the South packing houses." The explosion resulted in deaths of thirteen employees (including two contract employees) and approximately 28 employees that were hospitalized. Note: the injury line includes 48 workers with 14 killed and 32 hospitalized.

Keywords: AGRICULTURE, FIRE, EXPLOSION, SILO

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310988845 Hospitalized injury Cut/Laceration Occupation Not Listed
2 310988837 Hospitalized injury Cut/Laceration Occupation Not Listed
3 310988837 Hospitalized injury Cut/Laceration Occupation Not Listed
4 310988837 Hospitalized injury Cut/Laceration Occupation Not Listed
5 310988837 Hospitalized injury Cut/Laceration Occupation Not Listed
6 310988837 Hospitalized injury Cut/Laceration Occupation Not Listed
7 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
8 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
9 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
10 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
11 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
12 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
13 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
14 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
15 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
16 310988712 Fatality Burn/Scald(Heat) Occupation not reported
17 310988712 Fatality Burn/Scald(Heat) Occupation not reported
18 310988712 Fatality Burn/Scald(Heat) Occupation not reported
19 310988712 Fatality Burn/Scald(Heat) Occupation not reported
20 310988712 Fatality Burn/Scald(Heat) Occupation not reported
21 310988712 Fatality Burn/Scald(Heat) Occupation not reported
22 310988712 Fatality Burn/Scald(Heat) Occupation not reported
23 310988712 Fatality Burn/Scald(Heat) Occupation not reported
24 310988712 Fatality Burn/Scald(Heat) Occupation not reported
25 310988712 Fatality Burn/Scald(Heat) Occupation not reported
26 310988837 Fatality Burn/Scald(Heat) Occupation not reported
27 310988845 Fatality Burn/Scald(Heat) Occupation not reported
28 310988712 Fatality Burn/Scald(Heat) Occupation not reported
29 310988712 Fatality Burn/Scald(Heat) Occupation not reported
30 310988712 Hospitalized injury Burn/Scald(Heat) Occupation not reported
31 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
32 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
33 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
34 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
35 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
36 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
37 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
38 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
39 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
40 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
41 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
42 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
43 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
44 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
45 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
46 310988712 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed
47 310988845 Hospitalized injury Burn/Scald(Heat) Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close