Accident Summary Nr: 200902013 - Employee Cuts Buttocks While Using High-Pressure Water Hose

Accident Summary Nr: 200902013 -- Report ID: 0418400 -- Event Date: 06/18/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31098689806/20/20077699562998Mill Services Company, Inc.

Abstract: Employee #1 operated a "mole line", using a Water Jetting System where hi-pressure water is pumped to unclog a pipe or to pressure clean an area, in order to un-clog a drain, but did not have control over the foot pedal control box or "dead man" switch used to add or remove the high pressure water to the hose line. Employee #1 did not have foot control because the other employees had decided that the foot pedal would not work properly while under the existing two feet of muddy water in the settling basin and that the employees felt that Employee #1 wouldn't be able to see the foot pedal in the muddy water. It was decided that the foot switch could be controlled by another employee standing at the top of the settling basin and that this employee would operate the switch under the hand directions of Employee #1, the hose line operator, down in the settling basin. At the time of the accident, the high-pressure water was going through the hose line when the hose line became loose from the control of the operator and started to whip around the settling basin area where the operator was standing. Before the operator was able to get away from the high pressure water and before the employee at that top of the settling basin, controlling the foot pedal, was able to lift their foot off of the foot pedal and reduce the water pressure, Employee #1 sustained a severe laceration from the high-pressure water along his right upper thigh and right buttock area.

Keywords: BUTTOCKS, CLEANING, CONTROL LEVER, HOSE, LACERATION, HIGH PRESSURE, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310986898 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close