Accident Summary Nr: 200851640 - One employee killed when hydraulic platform collapses

Accident Summary Nr: 200851640 -- Report ID: 0215000 -- Event Date: 03/23/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30294053103/23/200017990M Track Enterprises Inc.

Abstract: Employee #1 and coworkers were on a hydraulic platform used to work on elevated train tracks when it collapsed and they fell approximately 20 ft. Employee #1 and eight coworkers were transported to the hospital; Employee #1 died as a result of his injuries on April 17, 2000.

Keywords: HOISTING MECHANISM, COLLAPSE, UNSECURED, CONSTRUCTION, HYDRAULIC TABLE, FALL, FALL PROTECTION, ELEVATED WORK PLAT, WORK PLATFORM
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge Maintenance or repair $1,000,000 to $5,000,000 22 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302940531 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 22 feet
Cause: Other Activities-Post Decking Detail Work
Fatality Cause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.