Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 200851608 - Employee dies of methylene chloride inhalation
Accident Summary Nr: 200851608 -- Report ID: 0215000 -- Event Date: 03/22/2000
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 302940762 | 04/10/2000 | 1793 | 0 | Custom Spraying And Reglazing Co., Inc. |
Abstract:
Employee #1 was working alone, stripping and reglazing a bathtub in a residential apartment. He was using government paint stripper that contained at least 70 percent methylene chloride. On returning home in the evening, the apartment owner found Employee #1 dead in the bathroom. Subsequent investigation revealed that he was overcome by methylene chloride vapors because of inadequate respiratory protection and insufficient ventilation in the work area. The medical examiner's report stated the cause of death as acute intoxication by methylene chloride.
Keywords:
VAPOR, VENTILATION, PPE, METHYLENE CHLORIDE, WORK RULES, CONSTRUCTION, INHALATION, PAINT SOLVENT, CHEMICAL VAPOR, TOXIC FUMES
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Single family or duplex dwelling |
Alteration or rehabilitation |
Under $50,000 |
|
|
X |
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
302940762 |
|
|
Fatality |
Poisoning(Systemic) |
Misc. metal,plastic,stone&glass-working mach. op's |