Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200850741 - Employee killed in fall into elevator pit

Accident Summary Nr: 200850741 -- Report ID: 0215000 -- Event Date: 11/05/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30061915211/06/199876990Horizon Elevator Co.

Abstract: Employee #1, an elevator maintenance worker, was standing on elevator #3 while he tried to fix elevator #2. As he jumped from elevator #3 to elevator #2, elevator #3 was activated and he became pinned in the raceway piping. Employee #1 then fell into the pit for elevator #2, and was killed.

Keywords: REPAIR, PINNED, WORK RULES, LOCKOUT, CAUGHT BETWEEN, PIT, FALL, ELEVATOR, ELEVATOR SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300619152 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close