Abstract: On July 10, 2002, Employee #1 and a coworker were demolishing an approximately 11 ft tall. sideless carport that was attached to a residential home. The home had been vacant for several years and it had just been recently been re-occupied. The workers used a chainsaw and cut out the sheathing boards between the rafters. Employee #1 then got on the roof of the carport and was taking down wiring that went to lightning rods on the home. He disconnected and separated the wiring into two lines. One line went to ground, the other up to the lightning rods. He was holding the two ends of the lines in each hand, making him part of a circuit, when he received an electric shock from old wiring going to the garage. The shock caused Employee #1 to fall off the roof and into a basement window well. Emergency Services was called and he was transported by ambulance to a hospital that was 20 miles away. Employee #1 was pronounced dead at the hospital from injuries sustained in the fall. The insulation on the wiring had worn off due to the wind; as a result, when the wind blew a certain way, the wires would arc, as evidenced by damage on the nearby fascia.

Keywords: ELEC INSULATION, ELECTRIC ARC, ROOF, DEMOLITION, WORK RULES, CONSTRUCTION, ELEC CIRC PART--MISC, ELECTRIC SHOCK, FALL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Demolition Under $50,000 1 10 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303816300 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 10 feet
Cause: Demolition
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.