Accident Summary Nr: 200831345 - Two Employees Are Injured When Load Falls

Accident Summary Nr: 200831345 -- Report ID: 0215600 -- Event Date: 08/05/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
30761187108/05/20081711238220Miller Mechanical Systems Llc

Abstract: On August 5, 2008, Employees #1 and #2 were installing underground plumbing conduit. A Grove AP308 crane lost its load of approximately 700-lb standpipe, which fell approximately 72 ft. Employees #1 and #2 jumped free, falling 12 ft. Employee #1 sustained cuts, bruises, and abrasions to his abdomen and Employee #2 sustained cuts, bruises, and abrasions to his knees. Employees #1 and #2 were not hospitalized.

Keywords: KNEE, LOADING, ABDOMEN, HOISTING MECHANISM, ABRASION, PLUMBING, WORK SURFACE, CONTUSION, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $20,000,000 and over 4 40

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307611871 Non Hospitalized injury Bruise/Contus/Abras Plumbers, pipefitters and steamfitters Distance of Fall: feet
Worker Height Above Ground/Floor: 12 feet
Cause: Installing underground plumbing conduit
Fatality Cause: Fall from/with platform catwalk (attached to struc
2 307611871 Non Hospitalized injury Bruise/Contus/Abras Plumbers, pipefitters and steamfitters Distance of Fall: feet
Worker Height Above Ground/Floor: 12 feet
Cause: Installing underground plumbing conduit
Fatality Cause: Fall from/with platform catwalk (attached to struc

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.