Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 200824043 - Employee Is Injured in Fall from Roof
Accident Summary Nr: 200824043 -- Report ID: 0521400 -- Event Date: 02/09/2009
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312723166 | 02/12/2009 | 1711 | 238220 | Advantage Mechanical Heating & Air Conditioning Co |
Abstract:
At approximately 11:00 a.m. on February 9, 2009, Employee #1 was working on the flat roof of a commercial building. He had removed the compressor from an existing HVAC system on the roof and was using a 2-wheeled cart to move it to a roof hatch that was being used as a means of access and egress, and for raising and lowering equipment. He was close to the edge of the roof when a pipe on the compressor caught the surface of the roof, causing the wheeled cart to be propelled forward. Employee #1 held onto the cart as it fell 25 ft to the ground below. Employee #1 suffered a fractured right femur, a shattered right arm and a shattered hip. He was hospitalized for treatment.
Keywords:
COMPRESSOR, FRACTURE, MAINTENANCE, ROOF, MANUAL MAT HANDLING, FALL, FALL PROTECTION, ARM, HIP, LEG
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Commercial building |
Maintenance or repair |
Under $50,000 |
2 |
25 |
|
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
312723166 |
|
|
Hospitalized injury |
Fracture |
Occupation not reported |