Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200821841 - Employee Ampuataes Arm in Hydraulic Press Accident

Accident Summary Nr: 200821841 -- Report ID: 0521400 -- Event Date: 07/08/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30515421310/24/20023363331521West Irving Die Cast, Inc.

Abstract: On July 8, 2002, an employee cycled a hydraulic press using "two-hand" controls. As the ram moved downward, the employee reached into the point of operation to remove the parts. The ram crushed his hand and arm, amputating his arm almost to his elbow. His amputation was treated at a hospital.

Keywords: HYDRAULIC RAM, POWER PRESS, TWO-HAND CONTROL, CRUSHED, POINT OF OPERATION, HYDRAULIC PRESS, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305154213 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.