Accident Summary Nr: 200810828 - Employee killed in fall from telecommunications tower

Accident Summary Nr: 200810828 -- Report ID: 0627400 -- Event Date: 10/29/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30058141010/31/200017310Jesse Craig Painting, Inc.

Abstract: Employees #1 and #2 were being hoisted up a 500 ft telecommunications tower to replace antenna parts damaged when the tower was struck by lightning. They were being raised by a 1/2 in. nylon rope load line using a friction winch. Employee #2 was attached to the load line by a pelican clip that was attached to a seat strap D-ring by a small clevis on his tree saddle safety belt. The pelican clip had been run through a hand-tied loop in the end of the rope load line. Employee #1 was attached to the same loop by the center clip of a short three-clip rope safety lanyard, as were the replacement antenna parts. The remaining clips were attached to the waist D-rings on her full body harness. The rope load line had been routed up the tower through a 3 in. McKissik top block pulley that had been hand-tied to the face of the tower by two pieces of 1/2 in. climbing rope, at a height of approximately 475 ft. The 1/2 in. nylon load line was then routed back down the tower and through a heel block pulley attached near the base. The free end was then wrapped around a cathead (capstan hoist) which had been bolted to the left rear wheel of a small pick-up truck, with the wheel jacked up off the ground. With the pickup truck idling, Employee #3 manually pulled on the free end of the rope, hoisting Employees #1 and #2 up the tower. The two employees were at a height of approximately 385 ft when the pickup's engine apparently stalled. When a coworker tried to restart the engine, friction was lost between the rope load line and the capstan hoist drum, causing Employees #1 and #2 to fall. They struck a guy at a height of about 210 ft and managed to ride it to the ground. Employee #1 was killed. Employee #2 suffered a fractured back, a fractured jaw, some fractured ribs, and other internal injuries. Employee #3 sustained severe rope burns to both hands from trying to stop the rope.

Keywords: FRACTURE, COMMUNICATION TOWER, HOISTING MECHANISM, TELECOM WORK, WORK RULES, CONSTRUCTION, FALL, ABRASIVE BURN, WINCH, MECH MALFUNCTION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Maintenance or repair Under $50,000 500 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300581410 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 270 feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Fall, other
2 300581410 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 270 feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Fall, other
3 300581410 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.