Accident Summary Nr: 200810190 - Two employees killed when natural gas pipeline explodes

Accident Summary Nr: 200810190 -- Report ID: 0627400 -- Event Date: 10/02/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
30057274010/03/199616230Ferguson Construction Co., Inc.

Abstract: Employees #1 and #2 were in a ditch, cold cutting a natural gas pipeline to install a new valve setting. When they broke the shell of the pipe, the nitrogen that was used to purge the pipe sprayed out under pressure. Employees #1 and #2 left the ditch, but later went back in while the nitrogen was still spraying out. They were replacing the valve setting when the pipe exploded violently. Employee #1 was thrown approximately 75 ft down the ditch and was covered with gravel, dirt, and rocks. Employee #2 was thrown about 20 ft and slammed into a segment of pipe. Both were killed. A lockout device located approximately six to seven miles to the northwest of the site had not been removed before the employees cut into the pipeline. With the lockout device in place, the line remained pressurized from the firegate valve to the site of the incident. The foreman who had originally applied the lockout device had to leave the area and did not inform anyone that the firegate was locked out. Also, because the acting lead person wanted to complete the test before leaving the area, Employees #1 and #2 were instructed to go back into the ditch near the cut in the line before it could be verified that the line was depressurized.

Keywords: INSTALLING, WORK RULES, CONSTRUCTION, NATURAL GAS, LOCKOUT, NITROGEN, EXPLOSION, HIGH PRESSURE, PIPELINE, COMMUNICATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300572740 Fatality Other Construction laborers
2 300572740 Fatality Other Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close